6000VA CyberPower Online S Tower Online UPS OLS6000E 2 Year Adv Replacement Warranty
Web ID: 20502
CYBERPOWER SYSTEMS Online S 6000VA/5400W Tower UPS, 20* 12V / 7AH, Terminal Block, USB & Serial Port & SNMP Slot, 2 Yrs Adv. Replaceme ONLY WHILE STOCKS LAST!
Manufacturer Warranty: 2 Year
Manufacturer PN: OLS6000E
Manufacturer Website
CyberPower OLS6000E is a high-performance UPS featuring online double-conversion topology, which provides seamless pure sine wave power for mission-critical devices such as NAS and servers, DVRs/surveillance systems, transportation and infrastructure, and emergency systems. It’s typically integrated in the back office, server room, and data center environment. By manually setting the UPS to ECO Mode, the UPS automatically detects the input power quality and discerns whether it should operate in Line Mode or ECO Mode. Under poor power conditions, the UPS will run in Line Mode, which guarantees the highest level of protection and the best possible power quality. When the input power quality is acceptable, the UPS switches to ECO Mode, which increases the total output power efficiency by up to 96%. The product is equipped with a Maintenance Bypass Switch. By flipping the switch, the power supply is safely transferred to utility. This allows service personnel to carry out fast on-site maintenance without having to shut down any connected equipment.
FEATURES
- Online (Double Conversion) UPS Topology
- Energy Saving Technology
- UPS Parallel Expansion
- Generator Compatible
- Overload Protection
- Maintenance Bypass Switch
- Zero Transfer Time
- Smart Battery Management (SBM)
- External Battery Module (EBM)
- Surge and Spike Protection
- EMI and RFI Filtration
- LCD Status Display
- Emergency Power Off (EPO) Port
- PowerPanel® Management Software
- SNMP/ HTTP Remote Management Capability
- Tower Form Factor
TYPICAL APPLICATION
- Data Closets
- NAS & Servers
- Home Theater Systems
- DVRs/Surveillance Systems
- POS Systems
- Transportation & Infrastructure
- Vehicle/Yacht
- Emergency Systems
- Electric Lighting
- Back Office
- Server Room
- Data Center
FEATURE FOCUS
Extended Runtime
Extended runtime is critical for most power demanding electronic devices. The installation of CyberPower's external battery modules allows scalable system runtime, guaranteeing higher system availability that ensures clean, uninterrupted power to protected equipment even during a power outage.
Smart Battery Management
Batteries are normally consider as a consumable item that requires replacement on a regular basis. To further prolong battery life span, UPS adopted with Smart Battery Management technology uses a 3-cycle approach and temperature compensation method which efficiently reduces battery maintenance cost and achieves a lower total cost of ownership.
GENERAL
UPS Topology
| Online Double Conversion |
Energy Saving Technology
| Online ECO Mode Efficiency > 96% |
Active PFC Compatibility
| Yes |
Parallel Expansion (Max. Units)
| 4 |
INPUT
Generator Compatibility
| Yes |
Nominal Input Voltage (Vac)
| 230 |
Input Voltage Range (Vac)
| 110 ~ 276 |
Adjustable Voltage Range (Vac)
| 0~80% Load for 110 ~ 276 Vac |
| 0~100% Load for 176 ~ 276 Vac |
Input Frequency (Hz)
| 50 ± 5 |
| 60 ± 6 |
Input Frequency Detection
| Auto-sensing |
Rated Input Current (A)
| 27.3 |
Input Power Factor
| 0.99 |
Input Connector Type
| Hardwire Terminal Block |
OUTPUT
Capacity (VA)
| 6000 |
Capacity (Watts)
| 5400 |
On Battery Waveform
| Pure Sine Wave |
On Battery Voltage(s) (Vac)
| 208 ± 1% |
| 220 ± 1% |
| 230 ± 1% |
| 240 ± 1% |
Output Voltage Setting
| Configurable |
On Battery Frequency (Hz)
| 50 ± 0.1% |
| 60 ± 0.1% |
Output Frequency Setting
| Configurable |
ECO Mode Voltage Tolerance
| ± 10 % |
Overload Protection
| Internal Current Limiting , Circuit Breaker , Fuse |
Overload Protection (Line Mode)
| 105~125% Load for 10 min, 125~150% Load for 1 min, 150~170% Load for 10 sec, >170% Load for 1 sec |
Overload Protection (Battery Mode)
| 105~125% Load for 2 min, 125~150% Load for 30 sec, >150% Load for 1 sec |
Overload Protection (Bypass Mode)
| 125~150% Load for 1 min, 150~170% Load for 10 sec, >170% Load for 1 sec |
Crest Factor
| 3 : 1 |
Harmonic Distortion (Linear Load)
| THD<2% |
Harmonic Distortion (Non-linear Load)
| THD<5% |
Internal Bypass
| Automatic Bypass |
Maintenance Bypass
| Yes |
Outlet(s) - Total
| 1 |
Outlet Type
| Hardwire Terminal Block x 1 |
Typical Transfer Time (ms)
| 0 |
BATTERY
Runtime at Half Load (min)
| 18 |
Runtime at Full Load (min)
| 7 |
Typical Recharge Time (Hours)
| 7 |
Maximum Charging Current (A)
| 1 |
Start On Battery
| Yes |
Smart Battery Management (SBM)
| Yes |
User Replaceable
| No |
Battery Type
| Sealed Lead-acid |
Single Battery Capacity (AH)
| 12 V 7 AH |
External Battery Module (EBM)
| BPSE240V47A |
Max. EBM Quantity
| 15 |
SURGE PROTECTION & FILTERING
Surge Suppression (Joules)
| 445 |
EMI/RFI Filtration
| Yes |
MANAGEMENT & COMMUNICATIONS
LCD Panel
| Yes |
LCD Information Display
| Operation Type , Power Status , Battery Status , Load Status , Fault & Warning , Other Information , Event & Log |
LCD Setting & Control
| Mode Setting , Alarm Setting , Input & Output , Battery Setting , Fault & Warning , Communication , Event & Log , Security Setting |
LED Indicators
| Line Mode , Battery Mode , Bypass Mode , UPS Fault |
HID Compliant USB Port(s)
| 1 |
Serial Port
| RS232 |
Dry Contact (with Relay)
| Optional |
Emergency Power Off (EPO) Port
| Yes |
Audible Alarms
| Battery Mode , Low Battery , Overload , Overcharge , Overheat , UPS Fault |
Power Management Software
| PowerPanel® Business Edition |
SNMP / HTTP Remote Monitoring
| Yes - with optional RMCARD205 |
PHYSICAL
Form Factor
| Tower |
Enclosure Construction
| Metal |
Color
| Black |
PHYSICAL SIZE - UPS MODULE
Dimensions (WxHxD) (mm.)
| 260 x 708 x 550 |
Weight (kg.)
| 70 |
PHYSICAL SIZE - BATTERY MODULE
Dimensions (WxHxD)
| 260 x 718 x 550 |
Weight (kg.)
| 105 |
SHIPPING DIMENSIONS
Dimensions (WxHxD) (mm.)
| 428 x 970 x 720 |
Weight (kg.)
| 82 |
ENVIRONMENTAL
Operating Temperature (°C)
| 0 ~ 40 |
Operating Relative Humidity (Non-condensing) (%)
| 0 ~ 90 |
Operating Elevation (feet/meters)
| ≤1000, Load Derated 1% per 100m from 1000m and 2000m |
Storage Temperature (°C)
| -15 ~ 45 |
Storage Relative Humidity (Non-condensing) (%)
| 0 ~ 95 |
Online Thermal Dissipation (BTU/hr)
| 1603 |
CERTIFICATIONS
Certifications
| CE |
RoHS
| Yes |
WARRANTY
Product Warranty Period (Year)2
Battery Warranty Period (Year)2