AJAX Loading

2000VA CyberPower OLS2000ERT2UA 1800W Pure Sine Wave UPS, *Bonus Cyberpower SNMP Card

Web ID: 29127

CyberPower OLS2000ERT2Ua Rack 2000VA/1800W Pure Sine Wave UPS, VA: 2000, Watts: 1800, Single Phase, Online Double Conversion UPS Topology, Active PFC Compatible, Nominal Input Voltage (Vac): 230 10%, Input Voltage Range (Vac): 160 ~ 300, Pure Sin Wave Battery Waveform, Configurable Output Frequency Setting, Rated Input Current (A): 9, Power Cord Length: 1.5m, BONUS CyberPower RMCARD205 SNMP Remote Management Card for UPS
Manufacturer Warranty: 2 Year
Manufacturer PN: OLS2000ERT2UA
GTIN: 4712856273847
Manufacturer Website

$989 

GENERAL

Phase

Single Phase

Form Factor

Rackmount, Tower

UPS Topology

Online Double Conversion

Energy Saving Technology

Online ECO Mode Efficiency > 95%

Active PFC Compatibility

Yes

INPUT

Generator Compatibility

Yes

Nominal Input Voltage ( Vac )

230 ± 10%

Input Voltage Range ( Vac )

190 ~ 300

Adjustable Voltage Range ( Vac )

0~30% Load for 80 ~ 300 Vac
0~50% Load for 120 ~ 300 Vac
0~75% Load for 160 ~ 300 Vac
0~90% Load for 190 ~ 300 Vac
0~100% Load for 200 ~ 300 Vac

Input Frequency ( Hz )

50 ± 10
60 ± 10

Input Frequency Detection

Auto-sensing

Rated Input Current ( A )

9

Input Power Factor

0.99

Input Connector Type

IEC C14

Detachable Power Cord Plug Type

AU x 1

Power Cord Length (ft.)

5

Power Cord Length (m.)

1.5

OUTPUT

Capacity (VA)

2000

Capacity (Watts)

1800

On Battery Waveform

Pure Sine Wave

On Battery Voltage(s) ( Vac )

208 ± 1 %
220 ± 1 %
230 ± 1 %
240 ± 1 %

Output Voltage Setting

Configurable

On Battery Frequency ( Hz )

50 ± 0.5%
60 ± 0.5%

Output Frequency Setting

Configurable

Power Factor

0.9

ECO Mode Voltage Tolerance

± 15 %

Overload Protection

Internal Current Limiting, Circuit Breaker, Fuse

Overload Protection (Line Mode)

110~120% Load for 1 min, >120% Load Immediately

Overload Protection (Battery Mode)

110~120% Load for 10 sec, >120% Load Immediately

Overload Protection (Bypass Mode)

>130% Load Immediately

Crest Factor

3 : 1

Harmonic Distortion (Linear Load)

THD<3%

Harmonic Distortion (Non-linear Load)

THD<5%

Internal Bypass

Automatic Bypass, Manual Bypass

Outlet(s) - Total

8

Outlet Type

IEC C13 x 8

Outlet(s) - Battery & Surge Protected

8

Outlet(s) - Critical Load (CL)

4

Outlet(s) - Non-Critical Load (NCL)

4

Typical Transfer Time ( ms )

0

BATTERY

Runtime at Half Load ( min )

13.1

Runtime at Full Load ( min )

3.8

Typical Recharge Time ( Hours )

4

Maximum Charging Current ( A )

1.5

Start On Battery

Yes

Smart Battery Management (SBM)

Yes

User-replaceable

Yes - Qualified Personnel Only

Battery Type

Sealed Lead-acid

Battery Cartridge (RBP)

RBP0157

Battery Cartridge (RBP) Quantity ( pcs )

1

Battery Quantity (Each RBP) ( pcs )

4

Battery Voltage (Each RBP) ( V )

48

Compatible Extended Battery Module (EBM)

BPSE48V40ART2U

Extended Battery Module Auto-detection

Yes

Max. EBM Quantity ( pcs )

3

SURGE PROTECTION & FILTERING

Surge Suppression ( Joules )

363

EMI/RFI Filtration

Yes

Phone/Network Protection RJ11/RJ45 (Combo)

1-in, 1-out

MANAGEMENT & COMMUNICATIONS

LCD Panel

Yes

LCD Types

Color LCD

LCD Information Display

Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log

LCD Setting & Control

Mode Setting, Alarm Setting, Input & Output, Battery Setting

HID Compliant USB Port(s)

1

Dry Contact (with Relay)

Yes

Emergency Power Off (EPO) Port

Yes

Audible Alarms

Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery

Management Cable ( pcs )

Power Cord x2, USB Cable x1

Power Management Software

PowerPanel Business (Recommended)

SNMP/HTTP Remote Monitoring

Yes - with optional RMCARD205

PHYSICAL

Enclosure Construction

Metal

Color

Black

Rackmount Rail

Yes

Rackmount Ears

Yes

PHYSICAL SIZE - UPS MODULE

Dimensions (WxHxD) (in.)

17.24 x 3.46 x 16.93

Dimensions (WxHxD) (mm.)

438 x 88 x 430

Weight (lbs.)

42.3

Weight (kg.)

19.2

Installed Rack Height ( U )

2

SHIPPING DIMENSIONS

Dimensions (WxHxD) (in.)

21.3 x 9 x 21.7

Dimensions (WxHxD) (mm.)

540 x 230 x 550

Weight (lbs.)

51.5

Weight (kg.)

23.4

ENVIRONMENTAL

Operating Temperature (°F)

32 ~ 104

Operating Temperature (°C)

0 ~ 40

Operating Relative Humidity (Non-condensing) ( % )

20 ~ 90

Operating Elevation ( feet/meters )

0-4,921 feet (0-1,500 meters)

Storage Temperature (°F)

-4 ~ 122

Storage Temperature (°C)

-20 ~ 50

Storage Relative Humidity (Non-condensing) ( % )

10 ~ 90

Storage Elevation ( feet/meters )

0-4,921 feet (0-1,500 meters)

Online Thermal Dissipation ( BTU/hr )

682

Variable Speed Fans

20 steps automatically

Audible Noise at 1.5M from Surface of Unit ( dBA )

45

CERTIFICATIONS

Certifications

CE, RCM

RoHS

Yes

WARRANTY

Product Warranty Period (Year)

2

Battery Warranty Period (Year)

2